HIGH PRESSURE CENTRIFUGAL BLOWER · YBCB-HP-919
Real static pressure. High volume. 2900 RPM.
The 919 series is a heavy-duty centrifugal turbo blower that holds up to 9149 Pa while moving 617 to 5153 m³/hr. Nine direct-drive trims from 0.75 to 18.5 kW for the extraction, combustion and conveying duties a low-pressure fan cannot hold.
- YBCB-HP-919-0.75: 617–761 m³/hr, 2231–2080 Pa
- YBCB-HP-919-1.5: 944–1141 m³/hr, 2689–2495 Pa
- YBCB-HP-919-2.2: 824–1264 m³/hr, 3584–3297 Pa
- YBCB-HP-919-3.0: 1410–1704 m³/hr, 3507–3253 Pa
- YBCB-HP-919-4.0: 1174–2062 m³/hr, 4003–4447 Pa
- YBCB-HP-919-5.5: 2500–3750 m³/hr, 3852–3407 Pa
- YBCB-HP-919-7.5: 3130–3680 m³/hr, 4910–4776 Pa
- YBCB-HP-919-11: 2622–3619 m³/hr, 7182–7019 Pa
- YBCB-HP-919-18.5: 3220–5153 m³/hr, 9149–9055 Pa
- Max static pressure
- 9149 Pa
- Airflow range
- 617–5153 m³/hr
- Motor Power
- 0.75–18.5 kW
- YBCB-HP-919 Series
- 9 Models
01Overview
Where the YBCB-HP-919 Series Sits
The YBCB-HP-919 series is nine direct-drive trims spanning 0.75 to 18.5 kW, quoted at 2900 RPM: airflow from 617 to 5153 m³/hr and static pressure up to 9149 Pa. It sits between a low-pressure ventilation fan and a positive-displacement machine — real static pressure and high volume from one direct-drive unit.
02READING THE CURVE
Every model is a line between two known points
A centrifugal blower does not have one flow and one pressure; it has a curve. The hero chart plots each 919 model as the segment between its two catalogue points — the loaded end, where it develops maximum static pressure at lower flow, and the open end, where flow is highest and pressure eases. Your installation operates where that curve crosses your system’s resistance line. Read the chart and you can see instantly which trims can reach your duty and which cannot.
The family climbs cleanly. The 0.75 kW trim sits low and left — a few hundred m³/hr at ~2 kPa. Step up through the range and both axes grow, until the 18.5 kW YBCB-HP-919-18.5 reaches past 9 kPa and 5000 m³/hr. Notice that the 11 kW trim develops higher pressure than the larger-flow 7.5 kW unit: on a centrifugal machine, a higher-pressure wheel is a different trade than a higher-flow one, even at similar power.
Because all of this is anchored to 2900 RPM, supply frequency is a first-order variable, not a footnote. Move to 60 Hz and the wheel spins faster; flow rises with speed and pressure rises with the square of speed. Always size against the curve at your actual supply frequency.
03Selection Guide
Sizing to Your Duty Point
Size on the static pressure the system actually needs first, then on air flow — a trim that cannot hold your resistance will not deliver its rated volume whatever its power rating. Read the two figures together in the specification table below and choose the trim whose operating window contains your duty point.
04PERFORMANCE DATA · 9 MODELS
Full YBCB-HP-919 specification table
Airflow and static pressure quoted as the curve endpoints at 2900 RPM, verbatim from the datasheet. Power is listed in both kW and HP. The model column stays pinned on mobile scroll.
Full specification · 9 models · Series YBCB-HP-919
0 – 21.75
0 – 4186.5
Showing 9 of 9 models
| Model | Power | Air Flow | Pressure(PA) | Sound Level(dB) | Weight(kg) | Action |
|---|---|---|---|---|---|---|
| YBCB-HP-919-0.75 | 0.75KW/1HP | 617-761 m3/hr | 2231-2080 PA | 84 | 39 | Get Quote |
| YBCB-HP-919-1.5 | 1.5KW/2 HP | 944-1141 m3/hr | 2689-2495 PA | 88 | 50 | Get Quote |
| YBCB-HP-919-2.2 | 2.2KW / 3 HP | 824-1264 m3/hr | 3584-3297 PA | 91 | 62 | Get Quote |
| YBCB-HP-919-3.0 | 3KW/4 HP | 1410-1704 m3/hr | 3507-3253 PA | 92 | 69 | Get Quote |
| YBCB-HP-919-4.0 | 4KW/5 HP | 1174-2062 m3/hr | 4003-4447 PA | 95 | 87 | Get Quote |
| YBCB-HP-919-5.5 | 5.5KW / 7.5 HP | 2500-3750 m3/hr | 3852-3407 PA | 95 | 108 | Get Quote |
| YBCB-HP-919-7.5 | 7.5KW/10 HP | 3130-3680 m3/hr | 4910-4776 PA | 98 | 133 | Get Quote |
| YBCB-HP-919-11 | 11KW/15 HP | 2622-3619 m3/hr | 7182-7019 PA | 99 | 169 | Get Quote |
| YBCB-HP-919-18.5 | 18.5KW/ 25 HP | 3220-5153 m3/hr | 9149-9055 PA | 105 | 240 | Get Quote |
05CONSTRUCTION & MOTOR
Heavy where high pressure demands it
Static pressure at 2900 RPM puts real load into the volute and the wheel, so the 919 is built stout: a rigid fabricated steel volute, a backward-curved high-pressure impeller dynamically balanced to run smooth at speed, and a substantial shaft and bearing arrangement. The rising shipping weight across the range — from 39 kg to 240 kg — is the honest signature of that rigidity, not padding.
Drive is direct: the impeller sits on the shaft of a 2-pole TEFC motor (IE2/IE3, IP55, F-class), so there is no belt to tension and no drive loss. Inlet and outlet are flanged for ducting; inlet filtration, silencers and anti-vibration mounts are specified to the installation. On abrasive dust duty, mount the blower on the clean side of the collector to keep the wheel out of the particulate stream.
06INSTALLATION & MAINTENANCE
Installation & Maintenance
Set the 919 on a rigid, level foundation with anti-vibration mounts sized to its mass — a heavy high-speed wheel transmits real dynamic load, and a flexible base makes noise and shortens bearing life. Confirm impeller rotation against the volute arrow before loading; a centrifugal wheel run backward moves a fraction of its rated air and masks the fault. Fit flexible connectors on inlet and outlet so duct forces and thermal growth never load the flanges.
Keep the wheel on clean air — on dust duty that means the clean-air side of the collector. Monitor bearing temperature and vibration; an ingested lump or built-up deposit unbalances the wheel and is the classic failure. Re-grease or replace bearings on schedule, inspect the impeller for wear and deposit at intervals, and keep silencer and filter elements serviced so the machine holds its curve.
Commissioning checklist
- Foundation level, anti-vibration mounts torqued to mass.
- Rotation checked against arrow; flow verified, not assumed.
- Flexible connectors fitted; ducting independently supported.
- Baseline current, bearing temp and vibration logged.
- Silencer / filter service interval set to the dust load.
07INDUSTRIAL DUTY
Built for high-resistance, round-the-clock air
The 919 series exists for the jobs where static pressure is the binding constraint — long ducts, dense filter media, deep beds and burner backpressure. These are continuous-duty machines, and the construction reflects it.
- High-resistance extraction — Fume, grinding-dust and fine-particulate collection through dense cartridge or bag media where a low-pressure fan would stall. The 919 holds face velocity against a loaded filter.
- Combustion & burner air — Forced-draught combustion air and burner supply that must overcome furnace and duct backpressure at a steady, high static figure.
- Pneumatic conveying — Higher-pressure dilute-phase conveying of powders and granules over longer runs than a CX turbo blower manages.
- Drying ovens & kilns — Recirculation and supply air for industrial drying and curing, pushing hot air through restrictive plenums and nozzle banks.
- Vacuum & hold-down at scale — Central vacuum and large hold-down platens where high static vacuum across a big area is needed from one machine.
- Process cooling & aeration — High-pressure cooling air and deep-bed aeration in metals, minerals, ceramics and chemical process plant.
083D / Interactive View
Inspect the Machine Closer
A rotatable 3D model is on the way. Until then the render shows the machine's form, its ports and its mounting arrangement — the same drawing-office view you get on the datasheet.
Interactive model — coming soon09Export Readiness
Ready to Ship Worldwide
High-pressure centrifugals are heavy, high-value machines, so packing protects the shaft, bearings and balanced wheel above all. We quote to your Incoterm, wind the motor to your supply frequency — decisive on a 2900 RPM machine — and pack for the sea or air route you choose.
- HS Code
- 8414
- Classification
- High-pressure centrifugal blowers classify under HS 8414. Confirm the destination sub-heading (blower vs industrial fan) with your customs broker.
- Incoterms
- FOB / CIF / EXW (Ex-Works Faridabad)
- Load Ports
- Nhava Sheva (JNPT) · Mundra · Delhi ICD (Tughlakabad)
- Export Packing
- Wheel and shaft locked against transit shock, bearings protected, unit bolted to a load-rated skid inside an ISPM-15 crate with marked lifting points and corner bracing for the heavier trims.
- Lead Time
- Smaller 0.75–4 kW trims typically ship in 2–3 weeks; 11–18.5 kW and special-voltage builds run 3–5 weeks. Curve selection at your frequency is confirmed before build.
- Power / Frequency
- Wound for 220–440 V, 50 Hz or 60 Hz on request
- Documentation
- Commercial invoice, packing list, ISO 9001:2015 certificate, test report, Certificate of Origin
10Frequently Asked Questions
Answers for Specifiers & Buyers
What makes the 919 series a 'high pressure' centrifugal blower?
Why is 2900 RPM called out on the curve?
How do I read the two airflow figures per model?
What duties is the 919 series built for?
Is it direct drive, and what motor is fitted?
The larger models are loud — how is noise managed?
11Who Builds It
Since 1998 — 26+ Years of Air Engineering in Faridabad
High-pressure centrifugals are a balancing and rigidity discipline — get the wheel or the volute wrong and the machine vibrates itself apart. Yash Blowers has built and matched them in Faridabad since 1998, and the 919 series is a proven continuous-duty platform trusted on extraction and combustion lines nationwide.
Every unit is run, checked against its rated curve and carries an ISO 9001:2015 certificate. With 10,000+ customers and hundreds of dispatches a day, the static-pressure figure we print is one the machine actually delivers.
Yash Blowers Private Limited has manufactured blowers and vacuum pumps from its ISO 9001:2015 plant in IMT Faridabad since 1998. Machining, assembly, balancing and testing are done in-house — so the machine you buy is the machine we built, backed by a 12-month warranty and a spares network that keeps decades-old units running.
ISO 9001:2015 · Made in India · 12-Month Warranty
- 1998
- Building air machines
- 26+
- Years in the trade
- 10,000+
- Customers served
- 300+
- Units dispatched / day
Request for Quotation
Get a Quote in 24 Hours
Send us your design airflow, system static pressure and supply frequency, and we will pick the 919 trim whose curve crosses your duty with headroom.
Send your duty point — flow, vacuum/pressure and destination port — and our engineers will size the right YBCB-HP-919 model and quote FOB, CIF or EXW. Export packing, HS classification and documentation handled in-house.