Skip to content
Yash BlowersYash Blowers

01AMC & Maintenance

Preventive maintenance · registered service file

Keep the air moving. Every shift.

A blower that is inspected on schedule outlives one that is fixed when it stops. Register your machines, choose how you want reminders, and an engineer sets an interval that matches your real duty.

← All service & support

02Why a contract beats a callout

A side channel blower has one moving assembly and no lubrication in the air path, which is exactly why it tolerates neglect for a long time — and then fails suddenly. The failure is rarely the machine. It is a loaded filter that starved the inlet, a discharge that was throttled until the unit dead-headed, a relief valve nobody verified, or bearings that ran past their hours. Every one of those is cheap to catch and expensive to repair.

An annual maintenance contract puts that checking on a calendar instead of on someone's memory. We hold your model codes, serials, commissioning dates and running hours on file, so the right spares travel with the engineer and the duty point gets verified against the figure the machine was sold on — not against a guess.

What an AMC typically covers

  • Scheduled inspection visits sized to your running hours
  • Inlet filter inspection and element replacement
  • Oil change for oil-sealed rotary vane pumps; carbon vane inspection for dry pumps
  • Impeller and side-channel inspection, clearance and deposit check
  • Bearing greasing or replacement per the manual and the hours run
  • Pressure relief valve setpoint verification
  • Motor electrical checks — current draw, phase balance, terminal tightness
  • Performance verification against the original duty point, with the readings left with you
  • Priority on spares because your models are already on file

Scope, visit frequency and price are confirmed on quotation. They depend on the model and quantity, the site, the ambient conditions and how hard the machines run — so we would rather size the contract properly than publish a number that does not fit your plant.

03Maintenance interval reference

Typical practice — confirm against your duty and ambient conditions

IntervalItemWhat to do
DailyListen and lookUnusual noise, vibration or smell; discharge temperature by hand-feel; filter bowl clear.
WeeklyInlet filterInspect the element. Replace on visible loading or when differential pressure climbs above the commissioning reading.
MonthlyDuty checkCompare working pressure or vacuum against the commissioning figure. Drift means a blockage, a leak or wear.
MonthlyMounting & guardsCheck fasteners, anti-vibration mounts, coupling guard and flexible connectors.
QuarterlyPRV verificationConfirm the relief valve still lifts at its setpoint — the single cheapest way to protect the machine.
QuarterlyMotor & electricalsTerminal tightness, insulation cleanliness, current draw against nameplate, phase balance.
Per manualOil change (oil-sealed rotary vane)Change on the interval in your manual, or sooner if the oil darkens, emulsifies or the level drops.
Per manualCarbon vane inspection (dry pumps)Measure vane height against the minimum in the manual and replace as a set.
AnnualBearingsRe-grease or replace per the manual and the running hours. Trend vibration if you have the instrumentation.
AnnualImpeller & side channelInspect for deposit build-up, erosion and clearance. Clean or replace the impeller if clearances have opened.

Typical practice, not a substitute for your machine's manual. Dust, humidity, ambient temperature and duty cycle all shorten these intervals. Isolate and lock off power before any inspection.

Need the consumables rather than the contract? The spare parts finder sizes the filter, relief valve and impeller band for your model, and the troubleshooting wizard walks a symptom back to its cause.

04Register for AMC

Tell us what is installed and how hard it runs. An engineer comes back with an interval, a scope and a quotation.

Include the country code.

Exactly as printed on the nameplate.

Duty drives the service interval.

Registration opens your service file. Reminder schedule and AMC scope are confirmed by an engineer — reminders are set up by our team, not auto-generated.

RFQ / طلب عرض سعر

Not sure which contract fits?

Send your model codes and running hours. An engineer sizes the interval and quotes the scope — ex-works Faridabad, or through our regional partner for on-site work abroad.

واتساب