Skip to content
Yash BlowersYash Blowers

SINGLE STAGE TURBINE BLOWER · YEBL-1

One impeller. Oil-free air. Six names.

The YEBL-1 is a single-stage regenerative blower — the machine your catalogue may call a ring, side channel, vortex or vacuum blower. Twenty-four trims span 0.25 to 24.5 HP, 80 to 1370 m³/hr, up to 460 mbar pressure and -340 mbar vacuum — from the same, single spinning wheel.

YEBL-1 · single-stage side-channel unitYB-FIG-01
Yash Blowers YEBL-1 single stage turbine blower — cast aluminium side-channel housing with axial cooling fan and TEFC motor
Models
24
Peak flow
1370 m³/hr
Air path
Oil-free
Motor Power
0.25–24.5 HP

01SIX NAMES · ONE MACHINE

Why this blower answers to six different names

Buyers in different industries learned the same machine under different labels, so the market carries six. Search for any of them and you land on the YEBL-1. The physics is identical — a single radial-vaned impeller spinning inside a crescent-shaped side channel. Understanding the names keeps you from over-buying a two-stage unit when a ring blower is exactly what your process needs.

  • Ring blowerThe side channel forms a ring around the impeller.
  • Side channel blowerNames the channel that regenerates the flow.
  • Regenerative blowerEnergy is added regeneratively, pass after pass.
  • Turbine blowerThe bladed impeller reads like a turbine wheel.
  • Vortex blowerAir spins in a vortex between vane and channel.
  • Vacuum blowerRun off the suction port, it is a vacuum source.

02WORKING PRINCIPLE

Regeneration: adding pressure one spin at a time

A ring blower does not slam air like a positive-displacement lobe pump, and it does not simply fling it outward like a plain centrifugal fan. It does both, repeatedly. As the impeller turns, each pocket of air between two vanes is thrown outward into the side channel by centrifugal force, decelerates, and is scooped back into the next deeper vane pocket closer to the hub. The air re-enters the blade path and is accelerated again.

That capture-and-return happens dozens of times as the air travels the arc from inlet to outlet — the flow is “regenerated” on every pass, and each pass adds a small increment of pressure. Stack enough small increments around the channel and a single stage lifts air to several hundred millibar with no pulsation and no contact between rotating and static parts.

Because the impeller never touches the housing, there is nothing to lubricate in the gas path and nothing to wear. The trade-off is characteristic: push more flow through a wider impeller and you regenerate fewer pressure steps per revolution, so peak pressure eases. That single relationship explains the entire 24-model spread below — high-pressure trims run narrow and slow on flow; high-flow trims run wide and modest on pressure.

03Selection Guide

Picking a Trim From 24

Fix the pressure or vacuum you must hold first: across the YEBL-1 range pressure spans 100 to 460 mbar and vacuum -100 to -340 mbar. Then size on airflow. The 24 trims cover 80 to 1370 m³/hr on 0.25 to 24.5 HP, so the same airflow is available at more than one power rating — the higher-power trim is the one that holds the higher pressure.

04PERFORMANCE DATA · 24 MODELS

Filter the range to your duty point

Every YEBL-1 trim, every column, verbatim from the datasheet. Set a minimum power and minimum airflow to narrow the 24 models to the ones that clear your requirement, then read across for pressure, vacuum, noise and shipping weight. Values are nominal at 415 V / 50 Hz on a clean, unrestricted port.

Note · YEBL-1370HP prints without the ‘-1-’ series segment on the brochure and its 187 kg mass is a large step over the 126 kg 24.5 HP trim — confirm the exact code and weight on your PI before finalising freight.

Full specification · 24 models · Series YEBL-1

any

0 – 24.5

any m³/hr

0 – 1370 m³/hr

Showing 24 of 24 models

Single Stage Turbine Blower YEBL-1 — full 24-model specification table.
ModelPowerDisplacement(m³/hr)Displacement(CFM)Vacuum(mbar)Pressure(mbar)Sound Level(dB)Weight(kg)Action
YEBL-1-250.25 HP8047-120120539Get Quote
YEBL-1-800.5 HP8047-1301406212Get Quote
YEBL-1-1451.0 HP14585-1501606314Get Quote
YEBL-1-210L1.5 HP210123-1701706422Get Quote
YEBL-1-2102.0 HP210123-1902007023Get Quote
YEBL-1-2652.0 HP265155-1701807025Get Quote
YEBL-1-3452.0 HP345203-1251257026Get Quote
YEBL-1-4162.0 HP416245-1001007029Get Quote
YEBL-1-2703.0 HP270158-2302506727Get Quote
YEBL-1-4203.0 HP420247-1801706930Get Quote
YEBL-1-320V4.0 HP320188-2702906937Get Quote
YEBL-1-4005.0 HP400235-2903307740Get Quote
YEBL-1-530L5.5 HP530312-2002007054Get Quote
YEBL-1-700F5.5 HP700412-1501407857Get Quote
YEBL-1-5307.5 HP530312-3003208062Get Quote
YEBL-1-7007.5 HP700412-2001808166Get Quote
YEBL-1-530P10 HP530312-3203808268Get Quote
YEBL-1-700P10 HP700412-2702608269Get Quote
YEBL-1-105011 HP1050618-2102107493Get Quote
YEBL-1-137011 HP1370806-1201107498Get Quote
YEBL-1-1050P16.5 HP1050618-28027074116Get Quote
YEBL-1-1370P16.5 HP1370806-19018074121Get Quote
YEBL-1-1050HP24.5 HP1050618-34046074126Get Quote
YEBL-1370HP24.5 HP1370806-31028074187Get Quote

05MATERIALS & CONSTRUCTION

Cast aluminium where it counts, cast iron where it must

Housing & cover

Pressure-die-cast aluminium alloy on the small and mid trims — light, corrosion-resistant and a good heat sink for the warm regenerated air. Larger high-HP frames move to cast iron for rigidity under sustained 24/7 load, which is one reason shipping weight climbs sharply on the top of the range.

Impeller

A single die-cast aluminium impeller with radial vanes, precision balanced so it can spin at motor speed with the tight impeller-to-channel clearance that regeneration depends on. It is the only wearing surface in the air path — replaceable as a spare from the YEBL-IMP impeller range.

Motor & seals

Close-coupled TEFC induction motor, IE2/IE3 efficiency, IP55, F-class insulation, impeller mounted directly on the shaft so there is no coupling to align. Lip seals and a machined side channel keep leakage low and the delivered air oil-free.

Every unit ships with an integral silencer on inlet and outlet, and an optional inlet filter and pressure/vacuum relief valve — the two accessories that most affect field life. Under-filtered air abrades the impeller; an unset relief valve lets the blower dead-head and overheat. Both are inexpensive insurance on a machine expected to run for years.

06INSTALLATION & MAINTENANCE

Installation & Maintenance

Mount the blower on a flat, rigid base with the shaft horizontal unless the datasheet permits otherwise, and leave clear space around the motor fan cowl — these machines are air-cooled and a blocked cowl is the most common cause of a nuisance thermal trip. Always fit a relief valve sized to the duty so the unit can never run fully dead-headed; a regenerative blower with a closed port converts all its shaft power into heat within minutes.

Fit an inlet filter and keep it clean. The tight running clearance that makes the blower efficient is the same clearance that a swallowed particle will score. On vacuum duty, protect the suction line from liquid carry-over. Support the pipe so its weight never hangs on the blower flanges, and use a short flexible connector to keep motor vibration and pipe strain apart.

Service interval, briefly

  • Check / clean inlet filter — weekly to monthly by dust load.
  • Confirm relief-valve setting and listen for pulsation on start.
  • Re-grease / replace motor bearings on the hour schedule.
  • Verify current draw against nameplate — a rising amp reading flags a clogged filter or a restricted line.
  • Inspect impeller clearance at overhaul; swap from YEBL-IMP if scored.

07WHERE IT RUNS

One blower, a dozen process lines

  • Effluent & STP aerationOil-free diffused-air aeration in sewage and effluent treatment. The 3–10 HP pressure trims feed fine-bubble diffusers at the 250–380 mbar most tank depths need.
  • Aquaculture & bioflocContinuous pond and biofloc aeration where any oil in the air would kill stock. Reliable 24/7 duty is the whole requirement, and the ring blower is built for it.
  • Pick-and-place vacuumRun off the suction port, mid trims hold vacuum for pick-and-place, printing feed tables, labelling and packaging lines that lift sheet and film on a vacuum cup.
  • Pneumatic conveyingLow-pressure dilute-phase conveying of powders and granules — dosing, de-dusting and vacuum lifting in food, plastics and pharma plants.
  • Electroplating agitationAir agitation of plating and rinse tanks. Oil-free air keeps the bath chemistry clean while high flow rolls the solution evenly across the work.
  • CNC & soldering extractionVacuum hold-down on routers and vacuum de-solder / fume draw on electronics benches, where compact, quiet, oil-free air is worth more than raw pressure.

083D / Interactive View

Inspect the Machine Closer

A rotatable 3D model is on the way. Until then the render shows the machine's form, its ports and its mounting arrangement — the same drawing-office view you get on the datasheet.

3D / Interactive ViewYB-3D-01
Single stage turbine blower — interactive 3D model placeholder showing the YEBL-1 side-channel housingInteractive model — coming soon

09Export Readiness

Ready to Ship Worldwide

Single stage turbine blowers ship worldwide as a compact, robust unit — motor and impeller are one assembly, so there is nothing to re-align on arrival. We quote and document to the Incoterm that suits your freight, and wind the motor for your grid before the crate is nailed.

HS Code
8414
Classification
Regenerative / side-channel blowers classify under HS 8414 (air or vacuum pumps, compressors, fans). Confirm the destination sub-heading with your broker.
Incoterms
FOB / CIF / EXW (Ex-Works Faridabad)
Load Ports
Nhava Sheva (JNPT) · Mundra · Delhi ICD (Tughlakabad)
Export Packing
Bolted to a skid inside an ISPM-15 heat-treated plywood crate, inlet/outlet ports capped, motor terminal box sealed against transit moisture. Palletised for the smaller trims, full crate for high-HP frames.
Lead Time
Popular 0.5–10 HP trims ship from stock or within 1–2 weeks. High-HP and special-voltage builds run 3–4 weeks. Consolidated multi-model orders are staged to one dispatch.
Power / Frequency
Wound for 220–440 V, 50 Hz or 60 Hz on request
Documentation
Commercial invoice, packing list, ISO 9001:2015 certificate, test report, Certificate of Origin

10Frequently Asked Questions

Answers for Specifiers & Buyers

Ring blower, side channel blower, regenerative blower — what is the difference?
None. They are five trade names for the exact same machine: a single impeller with radial vanes spinning inside a side channel that regenerates the air's velocity many times per revolution. 'Turbine', 'ring', 'side channel', 'regenerative', 'vortex' and 'vacuum blower' all describe the YEBL-1. Choose by duty point, not by name.
Is a single stage turbine blower oil-free?
Yes. The impeller is the only moving part in the air path and it never touches the housing, so there is no lubrication, no piston rings and no oil carry-over. Delivered air is 100% oil-free — the reason these blowers dominate aquaculture aeration, food handling and pharma vacuum where contamination is unacceptable.
How much pressure or vacuum can one stage produce?
Across the 24-model YEBL-1 range, pressure runs from 100 mbar on high-flow trims up to 460 mbar on the 24.5 HP YEBL-1-1050HP, and vacuum from -100 mbar to -340 mbar. A single stage trades pressure for flow — pick a double stage blower when you need more than ~330 mbar continuously at a given flow.
Can the same blower run as a pressure blower and a vacuum pump?
Yes. Air drawn into the inlet is exhausted at the outlet, so the same unit pressurises from the discharge port or evacuates from the suction port — never both simultaneously on one machine. Every YEBL-1 datasheet lists both its max pressure and max vacuum rating.
Which motor supply do you build for export orders?
Standard build is a TEFC IE2/IE3 induction motor wound for 415 V / 3-phase / 50 Hz. For export we wind 200–240 V or 380–460 V at 50 or 60 Hz to match your grid, and supply the motor nameplate and test report with the shipment. State voltage and frequency on the RFQ.
What maintenance does a ring blower need?
Very little. Keep the inlet filter clean, keep the cooling fan cowl clear, and re-grease or replace the two motor bearings on the manufacturer's hour schedule. With clean filtered air and correct relief-valve setting, the impeller and housing are effectively wear-free for years of 24/7 duty.
Why does airflow rise but pressure fall on the bigger single-stage trims?
A wider, higher-flow impeller moves more air but regenerates fewer pressure steps per pass, so peak pressure eases. That is why YEBL-1-416 gives 416 m³/hr at 100 mbar while YEBL-1-320V gives 320 m³/hr at 290 mbar on the same 2–4 HP class. Match the trim to whether your process is flow-led or pressure-led.

11Who Builds It

Since 1998 — 26+ Years of Air Engineering in Faridabad

Yash Blowers has built regenerative blowers in Faridabad since 1998 — more than 26 years of making one machine well before calling it six things. The YEBL-1 is our highest-volume family, which means the trim you order is a proven, repeatable build, not a one-off.

Every unit is tested to its datasheet point before it leaves the works and carries an ISO 9001:2015 quality certificate. That track record — 10,000+ customers, hundreds of units out the door each day — is why OEMs standardise on the YEBL-1 and stock our impellers as spares.

Yash Blowers Private Limited has manufactured blowers and vacuum pumps from its ISO 9001:2015 plant in IMT Faridabad since 1998. Machining, assembly, balancing and testing are done in-house — so the machine you buy is the machine we built, backed by a 12-month warranty and a spares network that keeps decades-old units running.

ISO 9001:2015 · Made in India · 12-Month Warranty

1998
Building air machines
26+
Years in the trade
10,000+
Customers served
300+
Units dispatched / day

Request for Quotation

Get a Quote in 24 Hours

Tell us whether your process is pressure-led or vacuum-led and we will map it to the right YEBL-1 trim.

Send your duty point — flow, vacuum/pressure and destination port — and our engineers will size the right YEBL-1 model and quote FOB, CIF or EXW. Export packing, HS classification and documentation handled in-house.

Direct line: +91 9971006400 · sales@yashblowers.org

WhatsApp