SOLSolution
60 Hz · 208 / 230 / 460 V (3-phase) · FOB Nhava Sheva or CIF US ports
High Pressure Blower for Electroplating in United States
High Pressure Blower sized for oil-free plating-bath air agitation and fume exhaust — 145–1,450 m³/hr at 100–300 mbar agitation — and built for the United States grid, climate and shipping route.
The high-pressure centrifugal blower is the natural choice for electroplating, and for United States the selection turns on 60 Hz power, destination Incoterms and the site environment. Because electroplating is oil-free plating-bath air agitation and fume exhaust, the machine must hold its duty continuously — 145–1,450 m³/hr at 100–300 mbar agitation — not just touch it on a test bench.
For United States, Yash winds the motor for 60 Hz at 208 / 230 / 460 V (3-phase). Motors are wound for 60 Hz at US voltages — a 50 Hz machine would overspeed ~20% and run past its rating on US supply. The shortlist below (YBCB-HP-919-2.2, YBCB-HP-919-4.0, YBCB-HP-919-5.5) is a starting point — real load figures turn it into a firm selection and a quote in 24 hours.
MDLRecommended models
High Pressure Blower — the fit for electroplating
For exhaust systems with long duct runs, tall scrubber packing or high static, where a general centrifugal runs out of head to hold capture velocity at the lip.
| Model | Power | Air flow | Pressure (Pa) | Noise (dB) | Weight (kg) |
|---|---|---|---|---|---|
| YBCB-HP-919-2.2 | 2.2KW / 3 HP | 824-1264 m3/hr | 3584-3297 PA | 91 | 62 |
| YBCB-HP-919-4.0 | 4KW/5 HP | 1174-2062 m3/hr | 4003-4447 PA | 95 | 87 |
| YBCB-HP-919-5.5 | 5.5KW / 7.5 HP | 2500-3750 m3/hr | 3852-3407 PA | 95 | 108 |
A 0.8–1.5 m bath needs clean 100–200 mbar air at the sparger; fume exhaust is a separate high-flow duty against hood and scrubber loss. Indicative only — final selection depends on your exact duty point, altitude and air temperature.
EXPBuilding for United States
- Frequency
- 60 Hz
- Three-phase voltage
- 208 / 230 / 460 V (3-phase)
- Single-phase
- 115 / 230 V
- Incoterms
- FOB Nhava Sheva or CIF US ports
- Ports
- US east coast · US west coast
- HS code
- 8414 — air/gas blowers, fans & compressors
Motors are wound for 60 Hz at US voltages — a 50 Hz machine would overspeed ~20% and run past its rating on US supply.
Aquaculture & RAS
Diffused-air aeration for domestic shrimp, RAS fish farms and pond systems — a fast-growing US market.
Municipal & industrial wastewater
Continuous aeration-basin and diffuser duty at treatment plants — 24/7 rated machines.
Pneumatic conveying
Vacuum and pressure conveying of powders, pellets and granules in processing plants.
OEM & packaging
Vacuum for pick-and-place, packaging and printing machinery built by US OEMs.
FAQHigh Pressure Blower for Electroplating — FAQs
Which High Pressure Blower model do I need for electroplating in United States?
For a typical electroplating duty of 145–1,450 m³/hr at 100–300 mbar agitation, start with YBCB-HP-919-2.2 and step through YBCB-HP-919-2.2, YBCB-HP-919-4.0, YBCB-HP-919-5.5 as the load rises. A 0.8–1.5 m bath needs clean 100–200 mbar air at the sparger; fume exhaust is a separate high-flow duty against hood and scrubber loss. Send us your exact flow and pressure and an engineer confirms the model and quotes it FOB Nhava Sheva or CIF US ports.
How do you ship a High Pressure Blower to United States?
Orders move FOB Nhava Sheva or CIF US ports, routed through your US port. Units are palletised and packed in seaworthy, ISPM-15 heat-treated wooden crates and declared under HS heading 8414. Commercial documents, certificate of origin and per-unit test certificates travel with the shipment on request; spares can follow by air freight.
RFQ / Request for Quotation
High Pressure Blower for Electroplating in United States?
Send your duty point (145–1,450 m³/hr at 100–300 mbar agitation), site voltage and destination port — an engineer sizes the model and quotes FOB Nhava Sheva or CIF US ports.