50 Hz · 380–415 V (3-phase) · CIF Jebel Ali (or FOB Nhava Sheva)

Double Stage Blower for Effluent Treatment Plants in Middle East

Double Stage Blower sized for activated-sludge and SBR aeration on variable industrial load — 150–1,100 m³/hr at 250–650 mbar — and built for the Middle East grid, climate and shipping route.

For a effluent treatment plant in Middle East, the double stage blower is the component the process leans on — and Yash builds it to the 250–650 mbar band the job needs, not to a generic datasheet. On this application the machine handles activated-sludge and SBR aeration on variable industrial load; Match discharge pressure to tank depth and diffuser resistance; a PRV caps back-pressure through settle and decant phases.

For Middle East, Yash winds the motor for 50 Hz at 380–415 V (3-phase). Motors are de-rated for 45–50 °C ambient and coastal corrosion protection is specified where the site sits near the sea. The shortlist below (YEBL-DS-230V, YEBL-DS-320V, YEBL-DS-520) is a starting point — real load figures turn it into a firm selection and a quote in 24 hours.

MDLRecommended models

Double Stage Blower — the fit for effluent treatment

Double Stage Turbine Blower

Higher pressure for deeper activated-sludge basins and long fine-bubble grids where a single stage runs short of head.

Recommended Double Stage Turbine Blower models for this duty
ModelPowerFlow (m³/hr)Flow (CFM)Vacuum (mbar)Pressure (mbar)Noise (dB)Weight (kg)
YEBL-DS-230V3.0 HP230135-2903607235
YEBL-DS-320V7.5 HP320188-4405007370
YEBL-DS-52015.0 HP520317-43066074123

Match discharge pressure to tank depth and diffuser resistance; a PRV caps back-pressure through settle and decant phases. Indicative only — final selection depends on your exact duty point, altitude and air temperature.

EXPBuilding for Middle East

Frequency
50 Hz
Three-phase voltage
380–415 V (3-phase)
Single-phase
220–240 V
Incoterms
CIF Jebel Ali (or FOB Nhava Sheva)
Ports
Jebel Ali · Dammam · Jeddah · Hamad · Sohar
HS code
8414 — air/gas blowers, fans & compressors

Motors are de-rated for 45–50 °C ambient and coastal corrosion protection is specified where the site sits near the sea.

Sewage & STP aeration

Continuous diffused-air aeration for sewage treatment plants across new urban districts — the single biggest blower pull in the region.

Desalination & water treatment support

Aeration, degassing and pneumatic duty supporting desalination and municipal water treatment plants along the coast.

Aquaculture

Diffused-air aeration for a growing Gulf aquaculture sector holding dissolved oxygen in intensive ponds and tanks.

Construction & cement

Pneumatic conveying and dust-handling for construction and cement plants — inlet filtration specified against fine abrasive dust; also serves oilfield-adjacent utility duty.

FAQDouble Stage Blower for Effluent Treatment Plants — FAQs

Is the Double Stage Blower rated for continuous effluent treatment duty?

Yes — the recommended YEBL-DS-230V, YEBL-DS-320V, YEBL-DS-520 are dynamically balanced and built for the 24/7 load that effluent treatment runs. The duty here is activated-sludge and SBR aeration on variable industrial load at 150–1,100 m³/hr / 250–650 mbar; the machine is selected to hold that point continuously, not just touch it on a test bench.

How is a Double Stage Blower sized for effluent treatment?

Sizing turns on two numbers — flow and pressure. Match discharge pressure to tank depth and diffuser resistance; a PRV caps back-pressure through settle and decant phases. On this duty most selections sit around 150–1,100 m³/hr at 250–650 mbar. Fix the duty point, add a design margin, and pick the smallest model that covers both; YEBL-DS-230V and YEBL-DS-320V are the usual starting points.