SOLSolution
50 Hz · 380–415 V (3-phase) · CIF your SE Asian port (or FOB Nhava Sheva)
Side Channel Blower for Vacuum Conveying in Asia
Side Channel Blower sized for dilute-phase pneumatic vacuum conveying — 200–1,050 m³/hr at 150–500 mbar vacuum — and built for the Asia grid, climate and shipping route.
Specifying a side channel blower for vacuum conveying in Asia comes down to one thing: matching the machine to the duty, then building it for the grid and climate it will actually run on. The engineering point for vacuum conveying is straightforward: Line length and vertical lift set the vacuum; conveying rate sets the airflow. Deeper vacuum keeps material entrained to the receiver. That puts most selections around 200–1,050 m³/hr at 150–500 mbar vacuum.
For Asia, Yash winds the motor for 50 Hz at 380–415 V (3-phase). Short transit from India's west coast keeps lead time in days, priced for high-volume regional sourcing. Recommended fits are YEBL-1-320V, YEBL-1-530, YEBL-1-700; send flow, pressure, site voltage and destination port and the quote comes back firm.
MDLRecommended models
Side Channel Blower — the fit for vacuum conveying
The default vacuum source for short-to-medium dilute-phase conveying in the 150–350 mbar range — one impeller, one filter to service.
| Model | Power | Flow (m³/hr) | Flow (CFM) | Vacuum (mbar) | Pressure (mbar) | Noise (dB) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| YEBL-1-320V | 4.0 HP | 320 | 188 | -270 | 290 | 69 | 37 |
| YEBL-1-530 | 7.5 HP | 530 | 312 | -300 | 320 | 80 | 62 |
| YEBL-1-700 | 7.5 HP | 700 | 412 | -200 | 180 | 81 | 66 |
Line length and vertical lift set the vacuum; conveying rate sets the airflow. Deeper vacuum keeps material entrained to the receiver. Indicative only — final selection depends on your exact duty point, altitude and air temperature.
EXPBuilding for Asia
- Frequency
- 50 Hz
- Three-phase voltage
- 380–415 V (3-phase)
- Incoterms
- CIF your SE Asian port (or FOB Nhava Sheva)
- Ports
- Chittagong · Ho Chi Minh City · Jakarta · Bangkok · Port Klang · Colombo
- HS code
- 8414 — air/gas blowers, fans & compressors
Short transit from India's west coast keeps lead time in days, priced for high-volume regional sourcing.
Textiles
Air-jet weaving, yarn cleaning, humidification and dust extraction across the Bangladesh and Vietnam spinning and weaving base.
Plastics & PET
Material conveying, drying-hopper air, blow-moulding assist and vacuum handling at converters and bottle plants.
Aquaculture
Diffused-air aeration for Southeast Asian shrimp ponds and RAS fish systems — 24/7 dissolved-oxygen duty.
Printing & packaging
Vacuum for sheet-feeding, pick-and-place, laminating and pouch handling on regional machinery.
FAQSide Channel Blower for Vacuum Conveying — FAQs
What about spares and lead time for a Asia order?
Yash casts impellers and makes filters and pressure-relief valves in-house, so the spare you need in two years is the same part on the same drawing. For Asia that means a predictable chain — fast movers held regionally, the rest by air freight — and a firm lead time confirmed with the quote. Ask for a spares package matched to your duty cycle.
Will the Side Channel Blower run on Asia power?
Yes. Units for Asia are wound for 50 Hz at 380–415 V (3-phase), so the machine hits its rated duty point on your supply without a frequency conversion. Short transit from India's west coast keeps lead time in days, priced for high-volume regional sourcing. Confirm your exact site voltage and phase on the enquiry and the build is matched to it.
RFQ / Request for Quotation
Side Channel Blower for Vacuum Conveying in Asia?
Send your duty point (200–1,050 m³/hr at 150–500 mbar vacuum), site voltage and destination port — an engineer sizes the model and quotes CIF your SE Asian port (or FOB Nhava Sheva).