SOLSolution
50 Hz · 380–415 V (3-phase) · CIF Mombasa / Durban / Lagos (or FOB Nhava Sheva)
High Pressure Blower for Dust Collection in Africa
High Pressure Blower sized for baghouse / cartridge collector draft and pulse-jet cleaning — 1,200–6,000 m³/hr at 2,000–9,000 Pa static — and built for the Africa grid, climate and shipping route.
A dust collection line runs on air, and in Africa the high-pressure centrifugal blower that feeds it must be wound for 50 Hz, packed for the sea crossing, and backed by real spares. In dust collection, the high-pressure centrifugal blower carries the baghouse / cartridge collector draft and pulse-jet cleaning load — 1,200–6,000 m³/hr at 2,000–9,000 Pa static is the band most sites land in.
In Africa, expect 50 Hz at 380–415 V (3-phase) and delivery CIF Mombasa / Durban / Lagos (or FOB Nhava Sheva). Genset-ready builds for unstable grid power, robust filtration for dust and heat, and an in-house spares pipeline for remote sites. Pick from YBCB-HP-919-5.5, YBCB-HP-919-7.5, YBCB-HP-919-11 against your duty window, then let an engineer verify the selection at your exact pressure, altitude and air temperature.
MDLRecommended models
High Pressure Blower — the fit for dust collection
Higher static headroom for long duct runs, deep filters and pulse-jet cleaning supply where a standard centrifugal fan runs out of pressure.
| Model | Power | Air flow | Pressure (Pa) | Noise (dB) | Weight (kg) |
|---|---|---|---|---|---|
| YBCB-HP-919-5.5 | 5.5KW / 7.5 HP | 2500-3750 m3/hr | 3852-3407 PA | 95 | 108 |
| YBCB-HP-919-7.5 | 7.5KW/10 HP | 3130-3680 m3/hr | 4910-4776 PA | 98 | 133 |
| YBCB-HP-919-11 | 11KW/15 HP | 2622-3619 m3/hr | 7182-7019 PA | 99 | 169 |
Static pressure climbs as the filter cake builds; pick a machine whose curve holds airflow across the full dirty-to-clean range. Indicative only — final selection depends on your exact duty point, altitude and air temperature.
EXPBuilding for Africa
- Frequency
- 50 Hz
- Three-phase voltage
- 380–415 V (3-phase)
- Incoterms
- CIF Mombasa / Durban / Lagos (or FOB Nhava Sheva)
- Ports
- Mombasa · Dar es Salaam · Durban · Lagos · Tema
- HS code
- 8414 — air/gas blowers, fans & compressors
Genset-ready builds for unstable grid power, robust filtration for dust and heat, and an in-house spares pipeline for remote sites.
Aquaculture
Diffused-air aeration for intensive tilapia, catfish and shrimp systems — holds dissolved oxygen in ponds, tanks and raceways across a fast-growing sector.
Mining & cement dust collection
Pressure and vacuum for pulse-jet baghouses and cartridge filters at crushers, transfer points, screens and bagging lines.
Municipal wastewater
Continuous aeration-basin and diffuser duty at treatment plants as cities grow and effluent rules tighten — 24/7 rated machines.
Agriculture & food processing
Grain aeration, drying, and pneumatic conveying of flour, feed and granules in processing and packing lines.
FAQHigh Pressure Blower for Dust Collection — FAQs
What about spares and lead time for a Africa order?
Yash casts impellers and makes filters and pressure-relief valves in-house, so the spare you need in two years is the same part on the same drawing. For Africa that means a predictable chain — fast movers held regionally, the rest by air freight — and a firm lead time confirmed with the quote. Ask for a spares package matched to your duty cycle.
Will the High Pressure Blower run on Africa power?
Yes. Units for Africa are wound for 50 Hz at 380–415 V (3-phase), so the machine hits its rated duty point on your supply without a frequency conversion. Genset-ready builds for unstable grid power, robust filtration for dust and heat, and an in-house spares pipeline for remote sites. Confirm your exact site voltage and phase on the enquiry and the build is matched to it.
RFQ / Request for Quotation
High Pressure Blower for Dust Collection in Africa?
Send your duty point (1,200–6,000 m³/hr at 2,000–9,000 Pa static), site voltage and destination port — an engineer sizes the model and quotes CIF Mombasa / Durban / Lagos (or FOB Nhava Sheva).