SOLSolution
60 Hz · 208 / 230 / 460 V (3-phase) · FOB Nhava Sheva or CIF US ports
Side Channel Blower for Sewage Treatment Plants in United States
Side Channel Blower sized for continuous 24/7 fine-bubble diffused aeration — 200–2,000 m³/hr at 300–600 mbar — and built for the United States grid, climate and shipping route.
Choosing a side channel blower for sewage treatment is a duty-point decision first and a logistics decision second; this page covers both for a shipment into United States. This is a continuous 24/7 fine-bubble diffused aeration duty: Pressure follows basin depth at roughly 100 mbar per metre; airflow follows the BOD load. Hold dissolved oxygen at 1.5–2.5 mg/L.
United States runs on 60 Hz at 208 / 230 / 460 V (3-phase); Motors are wound for 60 Hz at US voltages — a 50 Hz machine would overspeed ~20% and run past its rating on US supply. Recommended fits are YEBL-1-320V, YEBL-1-530, YEBL-1-700; send flow, pressure, site voltage and destination port and the quote comes back firm.
MDLRecommended models
Side Channel Blower — the fit for sewage treatment
Oil-free air to fine-bubble diffusers in shallow package and small-municipal basins around the 200–350 mbar band, on continuous duty.
| Model | Power | Flow (m³/hr) | Flow (CFM) | Vacuum (mbar) | Pressure (mbar) | Noise (dB) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| YEBL-1-320V | 4.0 HP | 320 | 188 | -270 | 290 | 69 | 37 |
| YEBL-1-530 | 7.5 HP | 530 | 312 | -300 | 320 | 80 | 62 |
| YEBL-1-700 | 7.5 HP | 700 | 412 | -200 | 180 | 81 | 66 |
Pressure follows basin depth at roughly 100 mbar per metre; airflow follows the BOD load. Hold dissolved oxygen at 1.5–2.5 mg/L. Indicative only — final selection depends on your exact duty point, altitude and air temperature.
EXPBuilding for United States
- Frequency
- 60 Hz
- Three-phase voltage
- 208 / 230 / 460 V (3-phase)
- Single-phase
- 115 / 230 V
- Incoterms
- FOB Nhava Sheva or CIF US ports
- Ports
- US east coast · US west coast
- HS code
- 8414 — air/gas blowers, fans & compressors
Motors are wound for 60 Hz at US voltages — a 50 Hz machine would overspeed ~20% and run past its rating on US supply.
Aquaculture & RAS
Diffused-air aeration for domestic shrimp, RAS fish farms and pond systems — a fast-growing US market.
Municipal & industrial wastewater
Continuous aeration-basin and diffuser duty at treatment plants — 24/7 rated machines.
Pneumatic conveying
Vacuum and pressure conveying of powders, pellets and granules in processing plants.
OEM & packaging
Vacuum for pick-and-place, packaging and printing machinery built by US OEMs.
FAQSide Channel Blower for Sewage Treatment Plants — FAQs
Will the Side Channel Blower run on United States power?
Yes. Units for United States are wound for 60 Hz at 208 / 230 / 460 V (3-phase), so the machine hits its rated duty point on your supply without a frequency conversion. Motors are wound for 60 Hz at US voltages — a 50 Hz machine would overspeed ~20% and run past its rating on US supply. Confirm your exact site voltage and phase on the enquiry and the build is matched to it.
What about spares and lead time for a United States order?
Yash casts impellers and makes filters and pressure-relief valves in-house, so the spare you need in two years is the same part on the same drawing. For United States that means a predictable chain — fast movers held regionally, the rest by air freight — and a firm lead time confirmed with the quote. Ask for a spares package matched to your duty cycle.
RFQ / Request for Quotation
Side Channel Blower for Sewage Treatment Plants in United States?
Send your duty point (200–2,000 m³/hr at 300–600 mbar), site voltage and destination port — an engineer sizes the model and quotes FOB Nhava Sheva or CIF US ports.