Skip to content
Yash BlowersYash Blowers

SOLSolution

50 Hz · 380–415 V (3-phase) · CIF Jebel Ali (or FOB Nhava Sheva)

Double Stage Blower for Aquaculture & Biofloc in Middle East

Double Stage Blower sized for diffused-air pond, biofloc and RAS aeration — 145–900 m³/hr at 150–440 mbar — and built for the Middle East grid, climate and shipping route.

Buyers across the UAE, Saudi Arabia, Qatar, Oman and the Levant sourcing a double stage blower for aquaculture and biofloc want the same envelope the premium brands occupy — at a landed cost Indian manufacturing can hold. Expect 145–900 m³/hr at 150–440 mbar for aquaculture and biofloc work; the double stage blower is matched to that duty so it neither throttles nor runs short of pressure.

Power in Middle East is 50 Hz / 380–415 V (3-phase); confirm the exact site voltage and the double stage blower hits its rated duty on your supply. Motors are de-rated for 45–50 °C ambient and coastal corrosion protection is specified where the site sits near the sea. The shortlist below (YEBL-DS-150V, YEBL-DS-320V, YEBL-DS-520) is a starting point — real load figures turn it into a firm selection and a quote in 24 hours.

MDLRecommended models

Double Stage Blower — the fit for aquaculture and biofloc

Double Stage Turbine Blower

For deeper ponds, RAS sumps and long diffuser grids where the diffusers sit 2 m+ down and a single stage cannot hold pressure.

Recommended Double Stage Turbine Blower models for this duty
ModelPowerFlow (m³/hr)Flow (CFM)Vacuum (mbar)Pressure (mbar)Noise (dB)Weight (kg)
YEBL-DS-150V3.0 HP15088-3304406627
YEBL-DS-320V7.5 HP320188-4405007370
YEBL-DS-52015.0 HP520317-43066074123

Diffuser depth of 1–2 m sets the pressure; stocking density and dissolved-oxygen target set the airflow. Indicative only — final selection depends on your exact duty point, altitude and air temperature.

EXPBuilding for Middle East

Frequency
50 Hz
Three-phase voltage
380–415 V (3-phase)
Single-phase
220–240 V
Incoterms
CIF Jebel Ali (or FOB Nhava Sheva)
Ports
Jebel Ali · Dammam · Jeddah · Hamad · Sohar
HS code
8414 — air/gas blowers, fans & compressors

Motors are de-rated for 45–50 °C ambient and coastal corrosion protection is specified where the site sits near the sea.

Sewage & STP aeration

Continuous diffused-air aeration for sewage treatment plants across new urban districts — the single biggest blower pull in the region.

Desalination & water treatment support

Aeration, degassing and pneumatic duty supporting desalination and municipal water treatment plants along the coast.

Aquaculture

Diffused-air aeration for a growing Gulf aquaculture sector holding dissolved oxygen in intensive ponds and tanks.

Construction & cement

Pneumatic conveying and dust-handling for construction and cement plants — inlet filtration specified against fine abrasive dust; also serves oilfield-adjacent utility duty.

FAQDouble Stage Blower for Aquaculture & Biofloc — FAQs

Is the Double Stage Blower rated for continuous aquaculture and biofloc duty?

Yes — the recommended YEBL-DS-150V, YEBL-DS-320V, YEBL-DS-520 are dynamically balanced and built for the 24/7 load that aquaculture and biofloc runs. The duty here is diffused-air pond, biofloc and RAS aeration at 145–900 m³/hr / 150–440 mbar; the machine is selected to hold that point continuously, not just touch it on a test bench.

How is a Double Stage Blower sized for aquaculture and biofloc?

Sizing turns on two numbers — flow and pressure. Diffuser depth of 1–2 m sets the pressure; stocking density and dissolved-oxygen target set the airflow. On this duty most selections sit around 145–900 m³/hr at 150–440 mbar. Fix the duty point, add a design margin, and pick the smallest model that covers both; YEBL-DS-150V and YEBL-DS-320V are the usual starting points.

RFQ / Request for Quotation

Double Stage Blower for Aquaculture & Biofloc in Middle East?

Send your duty point (145–900 m³/hr at 150–440 mbar), site voltage and destination port — an engineer sizes the model and quotes CIF Jebel Ali (or FOB Nhava Sheva).

WhatsApp