01 / Family
CX-Series Centrifugal Blower (YBCB-CX)
Accelerated cooling air across long power-cable cooling sections.
CLCables & Electrical
Sector solution / Power & control cable
Power and control cable plants run heavy extrusion and long cooling sections — cooling air and calibration vacuum govern both quality and throughput.
REQTypical duty requirements
Air & vacuum on a power-cable line
| Section | Duty | Recommended class |
|---|---|---|
| Long cooling section | Accelerated cooling air | CX centrifugal |
| Extrusion degassing | Process vacuum | Vacuum pump |
| Calibration | Dimensional vacuum | Vacuum pump |
| Panel / plant cooling | Positive-pressure air | Centrifugal blower |
CTXWhat this sector runs
Insulation and sheathing extrusion on power cable is thermally demanding, and the cooling section is correspondingly long; centrifugal air accelerates and steadies that cooling so the cable holds concentricity and wall spec at speed. This is the plant's headline air duty.
Vacuum handles degassing and calibration in the extrusion and cooling sections, controlling volatiles and dimensions. The recommended structure treats centrifugal cooling air and process calibration vacuum as the two systems a cable line is built around.
SOLRecommended Yash families
01 / Family
Accelerated cooling air across long power-cable cooling sections.
02 / Family
Process vacuum for degassing and calibration on heavy extrusion.
ENGEngineering notes
Heavier power-cable insulation carries more heat, so the cooling section is long and the demand on cooling air is correspondingly high. Accelerated, steady centrifugal air effectively shortens that cooling and holds the cable's concentricity as it sets. A drifting blower lengthens the effective cooling and risks concentricity; a balanced CX machine keeps airflow constant across the long section, which is why it is the recommended cooling class for heavy cable.
Holding a power cable concentric is a combined job: steady cooling air sets the geometry as it cools, and calibration vacuum seats the dimensions. Neither alone is enough. Pairing balanced CX cooling blowers with a YELV vacuum pump, each sized to its section, gives the line control over both wall spec and concentricity — the two properties that decide whether a heavy cable passes its dimensional and electrical checks.
Cooling blowers on a power-cable line run for the length of every campaign, so their efficiency shows up directly on the meter over a year. A blower sized to sit at its best operating point, rather than throttled down from an oversized machine, moves the same air for less power, and a dynamically balanced rotor holds that efficiency instead of losing it to vibration as it wears. Specifying the real cooling airflow and choosing a machine that meets it without a control valve doing the derating is the difference between a cooling section that costs what it should and one that quietly overspends every shift for years.
Orient Cables is a valued customer of Yash Blowers. Product recommendations on this page describe our standard solutions for the cable & electrical sector, not that company's specific installations.
WHYWhy Yash Blowers
Heavy cable extrusion punishes cooling and vacuum machinery, so a maker who rebuilds and re-supplies from India protects throughput. Yash Blowers has cast its own impellers in Faridabad since 1998 under ISO 9001:2015 and dispatches 300+ machines a day, keeping cooling blowers and vacuum pumps close.
FAQFrequently asked questions
Because heavier insulation carries more heat, needing more cooling length to set at line speed. Accelerated, steady centrifugal air shortens the effective cooling and holds concentricity — the reason the CX class is recommended here.
A combination of steady cooling air and calibration vacuum. The recommendation pairs CX cooling blowers with a YELV vacuum pump to hold both wall spec and concentricity.
It scales with the insulation mass — heavier walls carry more heat and need more cooling length to set at line speed. Accelerated, steady centrifugal air effectively shortens that requirement and holds concentricity, which is why sizing the CX cooling blowers to the real heat load, rather than a nominal figure, is what lets a power-cable line run at rated speed.
RFQ / Request for Quotation
Send your duty point — flow and pressure, or the vacuum you need — and an engineer sizes the right model and quotes ex-works Faridabad, FOB Nhava Sheva or CIF your port.